Section 114130.5 Of Article 1. Design And Construction From California Health And Safety Code >> Division 104. >> Part 7. >> Chapter 6. >> Article 1.
114130.5
. (a) Except for CIP equipment in operation before the
effective date of this part, CIP equipment shall meet the
characteristics of a food contact surface and shall be designed and
constructed so that cleaning and sanitizing solutions circulate
throughout a fixed system and contact all interior food-contact
surfaces and the system is self-draining or capable of being
completely drained of cleaning and sanitizing solutions.
(b) CIP equipment that is not designed to be disassembled for
cleaning shall be designed with inspection access points to ensure
that all interior food-contact surfaces throughout the fixed system
are being effectively cleaned.