Section 9633 Of Article 2. Structural And Material Requirements Of Community Mausoleums And Columbariums From California Health And Safety Code >> Division 8. >> Part 5. >> Chapter 5. >> Article 2.
9633
. Horizontal and vertical partitions separating crypts
comprising companion crypts or a nest of crypts entered through a
single crypt opening may be constructed of precast reinforced
concrete; provided, the horizontal partitions are not less than one
and one-half inches in thickness and the vertical nonbearing
partitions are not less than one inch in thickness, and vertical
partitions bearing any load are not less than three inches in
thickness, and provided the crypt walls enclosing the nest of crypts
are constructed as required in Section 9632. Crypts shall be vented
at roof level of the structure, and vents shall continue to a gravel
filled trench below the floor of the bottom crypt to provide adequate
circulation of air. Nonstructural horizontal and vertical partitions
separating columbarium niches may be constructed of precast
reinforced concrete or other incombustible material.